158 research outputs found

    Hyperpolarizability effects in a Sr optical lattice clock

    Full text link
    We report the observation of the higher order frequency shift due to the trapping field in a 87^{87}Sr optical lattice clock. We show that at the magic wavelength of the lattice, where the first order term cancels, the higher order shift will not constitute a limitation to the fractional accuracy of the clock at a level of 10−1810^{-18}. This result is achieved by operating the clock at very high trapping intensity up to 400400 kW/cm2^2 and by a specific study of the effect of the two two-photon transitions near the magic wavelength

    Controlling dipole-dipole frequency shifts in a lattice-based optical atomic clock

    Full text link
    Motivated by the ideas of using cold alkaline earth atoms trapped in an optical lattice for realization of optical atomic clocks, we investigate theoretically the perturbative effects of atom-atom interactions on a clock transition frequency. These interactions are mediated by the dipole fields associated with the optically excited atoms. We predict resonance-like features in the frequency shifts when constructive interference among atomic dipoles occur. We theoretically demonstrate that by fine-tuning the coherent dipole-dipole couplings in appropriately designed lattice geometries, the undesirable frequency shifts can be greatly suppressed.Comment: 14 pages, 4 figure

    Efficient magneto-optical trapping of Yb atoms with a violet laser diode

    Full text link
    We report the first efficient trapping of rare-earth Yb atoms with a high-power violet laser diode (LD). An injection-locked violet LD with a 25 mW frequency-stabilized output was used for the magneto-optical trapping (MOT) of fermionic as well as bosonic Yb isotopes. A typical number of 4×1064\times 10^6 atoms for 174^{174}Yb with a trap density of ∌1×108/\sim 1\times10^8/cm3^3 was obtained. A 10 mW violet external-cavity LD (ECLD) was used for the one-dimensional (1D) slowing of an effusive Yb atomic beam without a Zeeman slower resulting in a 35-fold increase in the number of trapped atoms. The overall characteristics of our compact violet MOT, e.g., the loss time of 1 s, the loading time of 400 ms, and the cloud temperature of 0.7 mK, are comparable to those in previously reported violet Yb MOTs, yet with a greatly reduced cost and complexity of the experiment.Comment: 5 pages, 3 figures, 1 table, Phys. Rev. A (to be published

    Possibility of an ultra-precise optical clock using the 61S0→63P0o6 ^1S_0 \to 6 ^3P^o_0 transition in 171,173^{171, 173}Yb atoms held in an optical lattice

    Full text link
    We report calculations designed to assess the ultimate precision of an atomic clock based on the 578 nm 61S0−−>63P0o6 ^1S_0 --> 6 ^3P^o_0 transition in Yb atoms confined in an optical lattice trap. We find that this transition has a natural linewidth less than 10 mHz in the odd Yb isotopes, caused by hyperfine coupling. The shift in this transition due to the trapping light acting through the lowest order AC polarizability is found to become zero at the magic trap wavelength of about 752 nm. The effects of Rayleigh scattering, higher-order polarizabilities, vector polarizability, and hyperfine induced electronic magnetic moments can all be held below a mHz (about a part in 10^{18}), except in the case of the hyperpolarizability larger shifts due to nearly resonant terms cannot be ruled out without an accurate measurement of the magic wavelength.Comment: 4 pages, 1 figur

    Accurate spectroscopy of Sr atoms

    Full text link
    We report the frequency measurement with an accuracy in the 100 kHz range of several optical transitions of atomic Sr : 1S0−3P1^1S_0- ^3P_1 at 689 nm, 3P1−3S1^3P_1- ^3S_1 at 688 nm and 3P0−3S1^3P_0- ^3S_1 at 679 nm. Measurements are performed with a frequency chain based on a femtosecond laser referenced to primary frequency standards. They allowed the indirect determination with a 70 kHz uncertainty of the frequency of the doubly forbidden 5s^2^1S_0- 5s5p^3P_0 transition of 87^{87}Sr at 698 nm and in a second step its direct observation. Frequency measurements are performed for 88^{88}Sr and 87^{87}Sr, allowing the determination of 3P0^3P_0, 3P1^3P_1 and 3S1^3S_1 isotope shifts, as well as the 3S1^3S_1 hyperfine constants.Comment: 12 pages, 16 figure

    Cold atom Clocks and Applications

    Full text link
    This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the 133^{133}Cs and 87^{87}Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of 1.6×10−14τ−1/21.6\times 10^{-14}\tau^{-1/2} where τ\tau is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of 2×10−162\times 10^{-16} at 50,000sforthefirsttimeforprimarystandards.Inaddition,theseclocksrealizetheSIsecondwithanaccuracyof50,000s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of 7\times 10^{-16},oneorderofmagnitudebelowthatofuncooleddevices.Inasecondpart,wedescribetestsofpossiblevariationsoffundamentalconstantsusing, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using ^{87}RbandRb and ^{133}$Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.Comment: 30 pages, 11 figure

    Bottom-Water Conditions in a Marine Basin after the Cretaceous–Paleogene Impact Event: Timing the Recovery of Oxygen Levels and Productivity

    Get PDF
    An ultra-high-resolution analysis of major and trace element contents from the Cretaceous–Paleogene boundary interval in the Caravaca section, southeast Spain, reveals a quick recovery of depositional conditions after the impact event. Enrichment/depletion profiles of redox sensitive elements indicate significant geochemical anomalies just within the boundary ejecta layer, supporting an instantaneous recovery –some 102 years– of pre-impact conditions in terms of oxygenation. Geochemical redox proxies point to oxygen levels comparable to those at the end of the Cretaceous shortly after impact, which is further evidenced by the contemporary macrobenthic colonization of opportunistic tracemakers. Recovery of the oxygen conditions was therefore several orders shorter than traditional proposals (104–105 years), suggesting a probable rapid recovery of deep-sea ecosystems at bottom and in intermediate waters.This research was supported by Projects CGL2009-07603, CGL2008-03007, CGL2012-33281 and CGL2012-32659 (Secretaría de Estado de I+D+I, Spain), Projects RNM-3715 and RNM 05212, and Research Groups RNM-178 and 0179 (Junta de Andalucía)

    Laser spectroscopy for breath analysis : towards clinical implementation

    Get PDF
    Detection and analysis of volatile compounds in exhaled breath represents an attractive tool for monitoring the metabolic status of a patient and disease diagnosis, since it is non-invasive and fast. Numerous studies have already demonstrated the benefit of breath analysis in clinical settings/applications and encouraged multidisciplinary research to reveal new insights regarding the origins, pathways, and pathophysiological roles of breath components. Many breath analysis methods are currently available to help explore these directions, ranging from mass spectrometry to laser-based spectroscopy and sensor arrays. This review presents an update of the current status of optical methods, using near and mid-infrared sources, for clinical breath gas analysis over the last decade and describes recent technological developments and their applications. The review includes: tunable diode laser absorption spectroscopy, cavity ring-down spectroscopy, integrated cavity output spectroscopy, cavity-enhanced absorption spectroscopy, photoacoustic spectroscopy, quartz-enhanced photoacoustic spectroscopy, and optical frequency comb spectroscopy. A SWOT analysis (strengths, weaknesses, opportunities, and threats) is presented that describes the laser-based techniques within the clinical framework of breath research and their appealing features for clinical use.Peer reviewe
    • 

    corecore